Hi,
I'm trying to connect to a GE Fanuc Versamx PLC, P/No IC200CPU001, using either straight through 9-pin serial RS232 cable to port 1, or 9-pin serial cable to SNP Adapter (P/No HE693SNP232R) to port 2. I'm using Proficy Machine Edition 8.0 which is fully licensed. I can only use Comm Port 1 on my laptop, as I only have access to 9-pin serial cables as I am currently offshore at the moment. The PLC CPU has only 2 communications ports, 9-pin RS232, and 15-pin RS485.
The problem I have is I don't have the original configuration code so I'm trying to lift the running code from PLC for a back-up. I'm unsure if the connection settings were changed on the original configuration. I have made hardware configuration within PME with the CPU as P/No IC200CPU001, validate target, and when I try to go online to target the connection times out after multiple retries.
I have tried setting Port 1 and Port 2 on the CPU hardware configuration to different baud rates, parity, stop bits etc, but still having issues connecting. The CPU knows that there is a connection trying to be established, as the Port 1 or Port 2 LED's will illuminate on each try of connection, but extinguish after a small period until next retry of connection.
I have also tried disabling then enabling Comm Port 1, and also allocating to different Comm Port to see if this has any effect, but no change.
I'm unsure if it's something I'm needing to set up within Proficy Machine Edition, or if it's due to the serial cables/adapters, Comm Port setup on laptop, or something else that I've not thought of.
Any help is appreciated. Thanks in advance.
I'm trying to connect to a GE Fanuc Versamx PLC, P/No IC200CPU001, using either straight through 9-pin serial RS232 cable to port 1, or 9-pin serial cable to SNP Adapter (P/No HE693SNP232R) to port 2. I'm using Proficy Machine Edition 8.0 which is fully licensed. I can only use Comm Port 1 on my laptop, as I only have access to 9-pin serial cables as I am currently offshore at the moment. The PLC CPU has only 2 communications ports, 9-pin RS232, and 15-pin RS485.
The problem I have is I don't have the original configuration code so I'm trying to lift the running code from PLC for a back-up. I'm unsure if the connection settings were changed on the original configuration. I have made hardware configuration within PME with the CPU as P/No IC200CPU001, validate target, and when I try to go online to target the connection times out after multiple retries.
I have tried setting Port 1 and Port 2 on the CPU hardware configuration to different baud rates, parity, stop bits etc, but still having issues connecting. The CPU knows that there is a connection trying to be established, as the Port 1 or Port 2 LED's will illuminate on each try of connection, but extinguish after a small period until next retry of connection.
I have also tried disabling then enabling Comm Port 1, and also allocating to different Comm Port to see if this has any effect, but no change.
I'm unsure if it's something I'm needing to set up within Proficy Machine Edition, or if it's due to the serial cables/adapters, Comm Port setup on laptop, or something else that I've not thought of.
Any help is appreciated. Thanks in advance.
Sep 24, 2018 Proficy Machine Edition (versions lower than 8.0) If you are running any of the above software, you should be concerned about your continued ability to interface with your PLCs. Apt-get install ssh-keygen. Exe editor. This guide will help you answer questions and briefly explain how to migrate your existing project files into GE’s latest programming software, Proficy Machine.
Proficy Machine Edition 9.5
- Proficy Machine Edition 8.5 Crack - Proficy machine edition 6.5 crack jug with White and Proficy machine edition 6.5 crack Hensel, gut up up. Customer Center Menu. There should be Proficy Machine Edition 9.00 or Proficy Machine Edition 9.00 with any released SIM to install the.
- GFK-1868R Proficy. Machine Edition. 8.00 1 1 Welcome Congratulations for purchasing a Proficy. Machine Edition. 8.00 product. This package provides all the tools necessary to create powerful control and HMI (human machine interface) applications for a variety of run-time targets; a truly scalable solution.